Yes, dental implant screws can be removed, but how they are removed depends on whether the implant is osseointegrated (fused to bone) or not, and on the condition of the internal screw that connects the prosthetic components to the implant body; a "screw" in this context can mean either the implant fixture itself or a separate abutment or healing screw, and the removal method differs for each.

The question hides an ambiguity in the word "screw." In implant dentistry, several distinct parts may be called screws: the implant fixture (the threaded titanium body placed in the jawbone), the cover screw or healing abutment used during early healing, the abutment screw that fastens a crown, bridge, or other prosthesis to the fixture, and sometimes a fracture screw or retrieval tool used when a broken screw fragment must be extracted. Each of these can be removed, but the difficulty, setting, and risk profile vary greatly.

The implant fixture: removing the part embedded in bone

The implant fixture is the portion that fuses with bone through osseointegration. It is designed to remain permanently, but it can be removed when clinical circumstances require it—for example, infection, nerve injury, fracture, severe bone loss, improper position, or a failed prosthesis that cannot be salvaged. The Straumann guidance retrieved for this question states plainly that "there might be circumstances that require a removal of an implant" and that its instructions cover "the whole Straumann® Dental Implant System." That is manufacturer-specific guidance, not a universal rule, but it confirms the general principle: removal is possible and sometimes necessary.

The key distinction the Straumann material draws is between non-osseointegrated and osseointegrated implants. A non-osseointegrated implant—one placed recently and not yet fused to bone—can often be removed with reverse torque or specialized retrieval tools. The retrieved excerpt notes that "tools for the removal of non-osseointegrated implants must only be used within 48 hours after implant insertion." That figure is a manufacturer instruction for a particular system and should not be read as a general biological deadline; it reflects the point at which early mechanical stability may still permit atraumatic removal. Once bone has grown against the surface, the situation changes.

An osseointegrated implant is mechanically locked into bone. Removing it usually requires a surgical approach: reflecting a flap, using reverse torque if the implant can be unscrewed, or employing a trephine or hollow drill to cut a cylinder of bone around the fixture. Trephination removes the implant together with a cuff of surrounding bone, which is why it is reserved for cases where preservation is not the priority. The clinician must assess the extent of osseointegration before planning removal—the Straumann document explicitly places that responsibility on the clinician—because the choice of technique hinges on how much bone is holding the implant.

Removal of an integrated implant is not a casual procedure. It can damage adjacent teeth, nerves, or the bone that would be needed for a future replacement. In many cases the better course is to treat the peri-implant infection, replace the prosthetic components, or perform explantation only when the implant is unsalvageable. This is why the answer to "can they be removed" is yes, but "should they be removed" is a clinical judgment that depends on the reason for removal and the alternatives.

Abutment screws and prosthetic screws

The abutment screw is the small screw that passes through the crown or abutment and threads into the implant's internal connection. These screws are routinely removed and replaced. A dentist loosens the abutment screw with a driver to take off a crown, adjust a prosthesis, or clean the connection. The screw itself is often discarded and replaced with a new one because the torque and wear of use can compromise its integrity. Removal of an abutment screw is a routine, low-risk procedure performed in a dental chair under local anesthesia when needed.

Cover screws and healing abutments are removed at the second-stage surgery or when the restoration phase begins. These are temporary components and are designed to come out.

Broken or stripped screws

A more difficult situation arises when an abutment screw fractures inside the implant or its head strips. In that case the screw fragment must be retrieved. Dentists use specialized extraction kits, including reverse-threaded retrieval tools, ultrasonic devices, or in some cases a small drill to remove the fragment. If the fragment cannot be retrieved, the implant itself may need to be removed. This is one of the scenarios where the word "screw" and the word "implant" blur together: a failed abutment screw can force explantation of an otherwise healthy fixture.

A stripped internal thread on the implant is a different problem: the screw hole itself is damaged. Repair options include tapping a new thread (if the implant design allows), using a repair kit, or removing the implant. Not every implant system offers these repair options, which is why the specific manufacturer's instructions matter.

What the retrieved evidence supports and what it does not

The Straumann documents confirm that implant removal is a recognized procedure with manufacturer-provided instructions, and that the approach differs between non-osseointegrated and osseointegrated implants. They also assign the assessment of osseointegration to the clinician. What the retrieved excerpts do not provide is a comprehensive clinical protocol, success rates, or jurisdiction-specific rules. The 48-hour figure for non-osseointegrated removal tools is a manufacturer instruction for that system, not a general standard applicable to all implants. The documents are also undated in the retrieved material, and the reference date of November 13, 2026, does not itself verify that the guidance is current; the applicable version should be checked against the manufacturer's current documentation.

Why the question is confusing

People often say "implant screw" when they mean the whole implant, and "screw" when they mean the tiny abutment screw. A patient asking whether the screw can be removed may be asking about a loose crown, a failed implant, or a broken component. The answer differs in each case: abutment screws come out routinely, implant fixtures come out surgically when necessary, and broken fragments require retrieval tools. The setting also matters—removal of an abutment screw is a chairside procedure, while explantation of an integrated fixture is a surgical procedure with bone consequences.

Practical distinctions to keep straight

Component Typical removal method Setting Reversible?
Cover screw / healing abutment Unscrewed with a driver Chairside Yes, replaced by new component
Abutment screw Unscrewed with a driver; often replaced Chairside Yes
Broken abutment screw fragment Retrieval kit, ultrasonics, or drilling Chairside or surgical Sometimes; may lead to implant removal
Non-osseointegrated implant Reverse torque or retrieval tool Surgical Yes, but timing-sensitive
Osseointegrated implant Reverse torque or trephination Surgical Yes, but bone loss and retreatment considerations apply

The table is a general map, not a protocol. Individual implant systems, bone quality, and the reason for removal change the appropriate technique.

What to check before any removal

The clinician should confirm the implant system and its current manufacturer instructions, assess osseointegration and bone support, identify whether the problem is the fixture or a prosthetic component, and consider whether repair or replacement of the prosthesis is a better alternative than explantation. The patient's medical history, smoking status, and periodontal condition affect healing after removal and the feasibility of a future implant.

In short, dental implant screws can be removed; abutment and cover screws are removed routinely, and implant fixtures are removed surgically when clinical conditions require it, with the technique and risk depending on how completely the fixture has fused to bone and on the specific implant system involved.